Email: [email protected]
Mobile No: 9599443291
Address: Massive Mobility, Plot-2, Spring House Coworking, Sector-43, Gurugram, Haryana, India – 122002.

Servotech 180-240 kW (Dual-Gun) DC EV Charger

₹18.33L

₹20L

(8.3%)

Booking Amount

(Valid Only for AC Chargers)

Product Details Summarized

The Servotech charger is a robust and efficient EV charging solution designed for 4-wheelers, offering dual CCS Type 2 output ports with a power factor of 0.98 and a maximum output current of 300A. It supports a wide voltage range of 200-1000V DC and operates efficiently even in extreme temperatures ranging from -20°C to 55°C. Equipped with advanced safety features including AC over-voltage, surge protection, and ground fault monitoring, the charger also includes a 15-minute battery backup for critical control systems. It offers multiple user authentication options such as RFID and OCPP-based mobile app interface, ensuring secure and seamless operation.

Additional information

Brand

Color

White

Number of Guns

Double

Features

4G LTE & GSM, App Support, Ethernet, OCPP Compliant, RFID, Touch Screen, Wi-Fi

Power Output

User Type

,

Vehicle Brand

, , , , , , ,

Vehicle Category

Best-in-class charging management solutions

 

We provide best-in-class charging management solutions for organizations and individuals of all types who are looking to seamlessly integrate and optimize their EV charging infrastructure, ensuring efficiency, scalability, and sustainability in their operations.

Product Description in Detail:

  • Voltage Rating
    • 3-Phase, 415Vac ± 10%
  • Input Frequency
    • 50 Hz ± 1.5Hz or better
  • Insolation
    • 1 Nos. MCCB at input in Charger
  • User Authentication
    • RFID, QR-Code Scan, OCPP-based Mobile App Interface
  • Input Supply Failure Backup
    • Battery backup for a minimum of 15 minutes for the control system and billing unit
    • Data logs synchronized with CMS during backup time, in case of drain out
  • No. of Output Ports
    • 2 Nos CCS Type 2
  • Output Cable
    • 5-meter cable length at a height between 0.4 m to 1.5 m as per IEC 61851-23, section 101.1.3
    • Voltage range up to 1000V (DC)
    • Connector must fulfill IATF 16949 automotive standard and ISO 9001
    • Tested by ARAI at Indian atmospheric condition or at an ambient temperature of 50°C, whichever is higher
  • Power Factor
    • 0.98
  • Current & Voltage THD
    • Compliant with IEC 61000-3-12
  • Output Current (Max)
    • 300 A (Gun)
  • Output Voltage
    • 200-1000V DC
  • Rated Outputs and Maximum Output Power
    • As per IEC 61851-23,101.2.1.1 except for the ambient temperature range
    • Temperature range: -20°C to 55°C as per Indian climatic conditions
  • Efficiency
    • 94% for load more than 50%
  • Cabling
    • Should be FR grade
  • Metering
    • To comply with IEC 62052-11 and IEC 62053-21
    • Independent DC and AC Energy Meter for each output and Input with cumulative
  • Operating Temperature
    • -10 to 55°C
  • Enclosure Protection
    • IP55 or better
  • Cooling Method
    • Natural / Forced
    • Natural / FAN Cooling
  • Applications
    • 4 wheelers compatible with CCS-2
  • Communication Between Charger and EV
    • CCS2: IEC 61851, PLC – DIN 70121 and ISO 15118
  • Keypad
    • Alpha-numeric keypad with minimum 12 keys
    • If touch screen is offered, it can be an integral part of the display
    • Metallic/Membrane type / Touch screen
  • Software
    • Software Upgradation through backend System through over the air
    • Any future Upgradation (latest version of OCPP or any other upgraded protocol) till the completion of CAMC period, the vendor would upgrade the same at no extra cost to OMCs.
  • AC Input Protections
    • AC Voltage Protection
      • AC Over-Voltage, AC Under-Voltage
    • AC Current Protection
      • AC Over Current/Short Circuit
    • AC Safety Protection
      • Residual current/Ground fault – (ELCB Required 30 mA)
    • Earth Monitoring
      • Earth Presence/Connection Monitoring
    • Ground Fault Protection
      • Ground Fault Protection
    • Surge Protection
      • Surge Protection minimum Class B SPD
      • SPD should have a valid test report from NABL accredited Lab having facility as per IEC 61643-11/KEMA/VDE – 4KV DM
    • Temperature Protection
      • Over temperature
    • ESD
      • Emergency Shut Button (ESD)
      • As per IEC 61000 for complete unit
    • EMI/EMC
      • Immunity to electrostatic discharge (IEC 61000-4-2)
      • Supply Voltage Dips and Interruptions (IEC 61000-4-11)
      • Fast Transient (IEC 6100-4-4)
      • Voltage surges (IEC 61000-4-5)
      • Radiated Electro Magnetic Disturbances
  • Humidity
    • 95% relative humidity, Non-condensing
  • Altitude
    • Up to 2000 m

Servotech 180-240 kW (Dual-Gun) DC EV Charger

Servotech Power Systems

₹18.33L

₹20L

(8.3%)

Booking Amount

(Valid Only for AC Chargers)

Product Details Summarized

Additional information

Brand

Color

White

Number of Guns

Double

Features

4G LTE & GSM, App Support, Ethernet, OCPP Compliant, RFID, Touch Screen, Wi-Fi

Power Output

User Type

,

Vehicle Brand

, , , , , , ,

Vehicle Category

Best-in-class charging management solutions

 

We provide best-in-class charging management solutions for organizations and individuals of all types who are looking to seamlessly integrate and optimize their EV charging infrastructure, ensuring efficiency, scalability, and sustainability in their operations.

Product Description in Detail:

  • Voltage Rating
    • 3-Phase, 415Vac ± 10%
  • Input Frequency
    • 50 Hz ± 1.5Hz or better
  • Insolation
    • 1 Nos. MCCB at input in Charger
  • User Authentication
    • RFID, QR-Code Scan, OCPP-based Mobile App Interface
  • Input Supply Failure Backup
    • Battery backup for a minimum of 15 minutes for the control system and billing unit
    • Data logs synchronized with CMS during backup time, in case of drain out
  • No. of Output Ports
    • 2 Nos CCS Type 2
  • Output Cable
    • 5-meter cable length at a height between 0.4 m to 1.5 m as per IEC 61851-23, section 101.1.3
    • Voltage range up to 1000V (DC)
    • Connector must fulfill IATF 16949 automotive standard and ISO 9001
    • Tested by ARAI at Indian atmospheric condition or at an ambient temperature of 50°C, whichever is higher
  • Power Factor
    • 0.98
  • Current & Voltage THD
    • Compliant with IEC 61000-3-12
  • Output Current (Max)
    • 300 A (Gun)
  • Output Voltage
    • 200-1000V DC
  • Rated Outputs and Maximum Output Power
    • As per IEC 61851-23,101.2.1.1 except for the ambient temperature range
    • Temperature range: -20°C to 55°C as per Indian climatic conditions
  • Efficiency
    • 94% for load more than 50%
  • Cabling
    • Should be FR grade
  • Metering
    • To comply with IEC 62052-11 and IEC 62053-21
    • Independent DC and AC Energy Meter for each output and Input with cumulative
  • Operating Temperature
    • -10 to 55°C
  • Enclosure Protection
    • IP55 or better
  • Cooling Method
    • Natural / Forced
    • Natural / FAN Cooling
  • Applications
    • 4 wheelers compatible with CCS-2
  • Communication Between Charger and EV
    • CCS2: IEC 61851, PLC – DIN 70121 and ISO 15118
  • Keypad
    • Alpha-numeric keypad with minimum 12 keys
    • If touch screen is offered, it can be an integral part of the display
    • Metallic/Membrane type / Touch screen
  • Software
    • Software Upgradation through backend System through over the air
    • Any future Upgradation (latest version of OCPP or any other upgraded protocol) till the completion of CAMC period, the vendor would upgrade the same at no extra cost to OMCs.
  • AC Input Protections
    • AC Voltage Protection
      • AC Over-Voltage, AC Under-Voltage
    • AC Current Protection
      • AC Over Current/Short Circuit
    • AC Safety Protection
      • Residual current/Ground fault – (ELCB Required 30 mA)
    • Earth Monitoring
      • Earth Presence/Connection Monitoring
    • Ground Fault Protection
      • Ground Fault Protection
    • Surge Protection
      • Surge Protection minimum Class B SPD
      • SPD should have a valid test report from NABL accredited Lab having facility as per IEC 61643-11/KEMA/VDE – 4KV DM
    • Temperature Protection
      • Over temperature
    • ESD
      • Emergency Shut Button (ESD)
      • As per IEC 61000 for complete unit
    • EMI/EMC
      • Immunity to electrostatic discharge (IEC 61000-4-2)
      • Supply Voltage Dips and Interruptions (IEC 61000-4-11)
      • Fast Transient (IEC 6100-4-4)
      • Voltage surges (IEC 61000-4-5)
      • Radiated Electro Magnetic Disturbances
  • Humidity
    • 95% relative humidity, Non-condensing
  • Altitude
    • Up to 2000 m

Product Description in Detail:

  • Voltage Rating
    • 3-Phase, 415Vac ± 10%
  • Input Frequency
    • 50 Hz ± 1.5Hz or better
  • Insolation
    • 1 Nos. MCCB at input in Charger
  • User Authentication
    • RFID, QR-Code Scan, OCPP-based Mobile App Interface
  • Input Supply Failure Backup
    • Battery backup for a minimum of 15 minutes for the control system and billing unit
    • Data logs synchronized with CMS during backup time, in case of drain out
  • No. of Output Ports
    • 2 Nos CCS Type 2
  • Output Cable
    • 5-meter cable length at a height between 0.4 m to 1.5 m as per IEC 61851-23, section 101.1.3
    • Voltage range up to 1000V (DC)
    • Connector must fulfill IATF 16949 automotive standard and ISO 9001
    • Tested by ARAI at Indian atmospheric condition or at an ambient temperature of 50°C, whichever is higher
  • Power Factor
    • 0.98
  • Current & Voltage THD
    • Compliant with IEC 61000-3-12
  • Output Current (Max)
    • 300 A (Gun)
  • Output Voltage
    • 200-1000V DC
  • Rated Outputs and Maximum Output Power
    • As per IEC 61851-23,101.2.1.1 except for the ambient temperature range
    • Temperature range: -20°C to 55°C as per Indian climatic conditions
  • Efficiency
    • 94% for load more than 50%
  • Cabling
    • Should be FR grade
  • Metering
    • To comply with IEC 62052-11 and IEC 62053-21
    • Independent DC and AC Energy Meter for each output and Input with cumulative
  • Operating Temperature
    • -10 to 55°C
  • Enclosure Protection
    • IP55 or better
  • Cooling Method
    • Natural / Forced
    • Natural / FAN Cooling
  • Applications
    • 4 wheelers compatible with CCS-2
  • Communication Between Charger and EV
    • CCS2: IEC 61851, PLC – DIN 70121 and ISO 15118
  • Keypad
    • Alpha-numeric keypad with minimum 12 keys
    • If touch screen is offered, it can be an integral part of the display
    • Metallic/Membrane type / Touch screen
  • Software
    • Software Upgradation through backend System through over the air
    • Any future Upgradation (latest version of OCPP or any other upgraded protocol) till the completion of CAMC period, the vendor would upgrade the same at no extra cost to OMCs.
  • AC Input Protections
    • AC Voltage Protection
      • AC Over-Voltage, AC Under-Voltage
    • AC Current Protection
      • AC Over Current/Short Circuit
    • AC Safety Protection
      • Residual current/Ground fault – (ELCB Required 30 mA)
    • Earth Monitoring
      • Earth Presence/Connection Monitoring
    • Ground Fault Protection
      • Ground Fault Protection
    • Surge Protection
      • Surge Protection minimum Class B SPD
      • SPD should have a valid test report from NABL accredited Lab having facility as per IEC 61643-11/KEMA/VDE – 4KV DM
    • Temperature Protection
      • Over temperature
    • ESD
      • Emergency Shut Button (ESD)
      • As per IEC 61000 for complete unit
    • EMI/EMC
      • Immunity to electrostatic discharge (IEC 61000-4-2)
      • Supply Voltage Dips and Interruptions (IEC 61000-4-11)
      • Fast Transient (IEC 6100-4-4)
      • Voltage surges (IEC 61000-4-5)
      • Radiated Electro Magnetic Disturbances
  • Humidity
    • 95% relative humidity, Non-condensing
  • Altitude
    • Up to 2000 m
WhatsApp Image 2024-08-13 at 12.36.07 (1)

Flextron FLX-MAX 7.5kW AC EV Charger

₹26,250-₹28,875

Onwards
image-removebg-preview (25)

Massive Mobility 3.3 kW AC EV Charger for 2w/3w

₹12,000

Onwards
Screenshot-2024-08-14-232811

Delta 180 kW/ 240 kW DC EV Charger

₹15.96L - ₹18.06L

Onwards

Confused to choose a charger which fits your needs?

Picture from 1901 of an electric car

The History of Electric Cars (EV)

Explore the surprisingly long history of electric vehicles. Start from 1830s with dawn of EVs, go through 1900s when electric cars dominated the roads, move through the 60s, when ICE rose to popularity, and cruise through the 21st century to understand the rebirth of electric vehicle in automobile industry.

Keep Reading →

1C your end to end electric vehicle charging partner

1C is your all-in-one solution for electric vehicle charging, delivering complete services from installation to ongoing management. Count on us to handle every detail of your EV charging infrastructure with precision and care.

Unlock the Latest Price!

Up to 10% off on your favorite EV charger

Prices on EV chargers can fluctuate based on the latest industry trends and manufacturer updates. Click below to see if today’s price gives you an even better deal. Get the most accurate and up-to-date pricing directly from top OEMs, tailored just for you!